Fault finder: Open-collector wired AND
7 checks for this build on the Nano. Work from the top: power first, then each part, then the code.
0 of 7 checked
Power🔧 DC volts, 20 V rangeCheck 1 of 7
Nano supply pin
Plug the Nano into USB. Black probe on a GND pin, red probe on the 5V pin of the board.
You should see: 4.6 to 5.3 V
Readings are compared with the ranges for this build's parts. A meter on the wrong range or a loose probe gives odd numbers: check those first.
Common faults in this build
Both always read 0: what should I check?
Check the pull-up resistor goes to 5V and not GND.
Neither responds to the magnet: what should I check?
Turn the magnet round or try the other face.
Sensor gets warm: what should I check?
Disconnect, the power pins may be swapped.
Joined wire stays low: what should I check?
A magnet may be left near one of the sensors.
No serial text: what should I check?
Set 9600 baud.