Fault finder: Ohm's law lab with a multimeter
5 checks for this build on the board. Work from the top: power first, then each part, then the code.
0 of 5 checked
Power🔧 DC volts, 20 V rangeCheck 1 of 5
board supply pin
Plug the board into USB. Black probe on a GND pin, red probe on the 5V pin of the board.
You should see: 4.6 to 5.3 V
Readings are compared with the ranges for this build's parts. A meter on the wrong range or a loose probe gives odd numbers: check those first.
Common faults in this build
Meter reads zero current: what should I check?
The meter's red probe is in the wrong socket or the fuse is blown.
Current is much lower than predicted: what should I check?
Batteries are weak or the meter's own burden voltage matters on the 200 µA range. Use the 20 mA range.
Voltage reading is lower than the battery's: what should I check?
The batteries sag under load. Note it.
Resistor warms up: what should I check?
Not with these values. Check you did not use the wrong resistor or voltage.