Fault finder: Ohm's law lab with a multimeter

5 checks for this build on the board. Work from the top: power first, then each part, then the code.

0 of 5 checked
Power🔧 DC volts, 20 V rangeCheck 1 of 5

board supply pin

Plug the board into USB. Black probe on a GND pin, red probe on the 5V pin of the board.

You should see: 4.6 to 5.3 V

V

Readings are compared with the ranges for this build's parts. A meter on the wrong range or a loose probe gives odd numbers: check those first.

Common faults in this build

Meter reads zero current: what should I check?

The meter's red probe is in the wrong socket or the fuse is blown.

Current is much lower than predicted: what should I check?

Batteries are weak or the meter's own burden voltage matters on the 200 µA range. Use the 20 mA range.

Voltage reading is lower than the battery's: what should I check?

The batteries sag under load. Note it.

Resistor warms up: what should I check?

Not with these values. Check you did not use the wrong resistor or voltage.