Fault finder: Milk cooler temperature logger

12 checks for this build on the Uno. Work from the top: power first, then each part, then the code.

0 of 12 checked
Power🔧 DC volts, 20 V rangeCheck 1 of 12

Uno supply pin

Plug the Uno into USB. Black probe on a GND pin, red probe on the 5V pin of the board.

You should see: 4.6 to 5.3 V

V

Readings are compared with the ranges for this build's parts. A meter on the wrong range or a loose probe gives odd numbers: check those first.

Common faults in this build

LCD blank: what should I check?

Try address 0x3F, or turn the contrast screw.

Reads -127: what should I check?

Probe not connected or the pull-up resistor missing.

No SD rows: what should I check?

Format FAT32 and check CS on D10.

Wrong time: what should I check?

RTC not set, or the coin cell is flat.

Alarm too sensitive: what should I check?

Raise ALARM_AFTER_MIN.