Fault finder: Milk cooler temperature logger
12 checks for this build on the Uno. Work from the top: power first, then each part, then the code.
0 of 12 checked
Power🔧 DC volts, 20 V rangeCheck 1 of 12
Uno supply pin
Plug the Uno into USB. Black probe on a GND pin, red probe on the 5V pin of the board.
You should see: 4.6 to 5.3 V
Readings are compared with the ranges for this build's parts. A meter on the wrong range or a loose probe gives odd numbers: check those first.
Common faults in this build
LCD blank: what should I check?
Try address 0x3F, or turn the contrast screw.
Reads -127: what should I check?
Probe not connected or the pull-up resistor missing.
No SD rows: what should I check?
Format FAT32 and check CS on D10.
Wrong time: what should I check?
RTC not set, or the coin cell is flat.
Alarm too sensitive: what should I check?
Raise ALARM_AFTER_MIN.