Fault finder: Maximum power transfer lab

7 checks for this build on the board. Work from the top: power first, then each part, then the code.

0 of 7 checked
Power🔧 DC volts, 20 V rangeCheck 1 of 7

board supply pin

Plug the board into USB. Black probe on a GND pin, red probe on the 5V pin of the board.

You should see: 4.6 to 5.3 V

V

Readings are compared with the ranges for this build's parts. A meter on the wrong range or a loose probe gives odd numbers: check those first.

Common faults in this build

Peak is not at 470 ohms: what should I check?

The pot may not be linear or its range does not reach 470 ohms.

Voltage never changes: what should I check?

Check the meter is across the pot and the pot is wired as a variable resistor.

Power numbers look huge: what should I check?

Convert millivolts and milliwatts carefully.

Battery voltage sags: what should I check?

The battery is tired, so use a fresh one.

Readings wander: what should I check?

Hold the pot still and clean the contacts by turning it a few times.