Fault finder: Door opening counter

11 checks for this build on the Nano. Work from the top: power first, then each part, then the code.

0 of 11 checked
Power🔧 DC volts, 20 V rangeCheck 1 of 11

Nano supply pin

Plug the Nano into USB. Black probe on a GND pin, red probe on the 5V pin of the board.

You should see: 4.6 to 5.3 V

V

Readings are compared with the ranges for this build's parts. A meter on the wrong range or a loose probe gives odd numbers: check those first.

Common faults in this build

Counts twice per opening: what should I check?

Increase the 150 ms debounce or fix the magnet more firmly.

Never counts: what should I check?

Check the reed wiring and the gap, reed switches work within about 1 cm.

Count lost after power cut: what should I check?

It saves hourly, lower SAVE_EVERY_MS for testing only.

Display blank: what should I check?

Try address 0x3D, and check the display voltage.

Reed switch glass broken: what should I check?

Mount it with tape and do not bend its leads near the glass.