Projects / Pocket logic probe / Fault finder

Fault finder: Pocket logic probe

7 checks for this build on the board. Work from the top: power first, then each part, then the code.

0 of 7 checked
Power🔧 DC volts, 20 V rangeCheck 1 of 7

board supply pin

Plug the board into USB. Black probe on a GND pin, red probe on the 5V pin of the board.

You should see: 4.6 to 5.3 V

V

Readings are compared with the ranges for this build's parts. A meter on the wrong range or a loose probe gives odd numbers: check those first.

Common faults in this build

All three LEDs lit: what should I check?

An unused input is floating. Tie pins 9, 11 and 13 to GND.

LEDs very dim: what should I check?

The supply is below 3 V or LEDs are in the wrong direction.

Yellow never lights: what should I check?

Check the 1N4148 direction: its stripe (cathode) points to the node.

Probe reads wrong levels: what should I check?

The circuit under test uses 3.3 V and the probe's red lead is on 5 V. Power it from the same rail.