Fault finder: Liquid density meter
11 checks for this build on the Nano. Work from the top: power first, then each part, then the code.
0 of 11 checked
Power🔧 DC volts, 20 V rangeCheck 1 of 11
Nano supply pin
Plug the Nano into USB. Black probe on a GND pin, red probe on the 5V pin of the board.
You should see: 4.6 to 5.3 V
Readings are compared with the ranges for this build's parts. A meter on the wrong range or a loose probe gives odd numbers: check those first.
Common faults in this build
Reading is negative: what should I check?
Swap the A+ and A- wires.
Reading drifts: what should I check?
Wait for the load cell to warm up and keep it away from drafts.
Wrong by a fixed factor: what should I check?
Recalibrate with a known weight.
Jumpy numbers: what should I check?
Fix the load cell firmly and keep wires still.
Display blank: what should I check?
Check the OLED address 0x3C.