Fault finder: Liquid density meter

11 checks for this build on the Nano. Work from the top: power first, then each part, then the code.

0 of 11 checked
Power🔧 DC volts, 20 V rangeCheck 1 of 11

Nano supply pin

Plug the Nano into USB. Black probe on a GND pin, red probe on the 5V pin of the board.

You should see: 4.6 to 5.3 V

V

Readings are compared with the ranges for this build's parts. A meter on the wrong range or a loose probe gives odd numbers: check those first.

Common faults in this build

Reading is negative: what should I check?

Swap the A+ and A- wires.

Reading drifts: what should I check?

Wait for the load cell to warm up and keep it away from drafts.

Wrong by a fixed factor: what should I check?

Recalibrate with a known weight.

Jumpy numbers: what should I check?

Fix the load cell firmly and keep wires still.

Display blank: what should I check?

Check the OLED address 0x3C.