Fault finder: Battery level indicator with zeners

7 checks for this build on the board. Work from the top: power first, then each part, then the code.

0 of 7 checked
Power🔧 DC volts, 20 V rangeCheck 1 of 7

board supply pin

Plug the board into USB. Black probe on a GND pin, red probe on the 5V pin of the board.

You should see: 4.6 to 5.3 V

V

Readings are compared with the ranges for this build's parts. A meter on the wrong range or a loose probe gives odd numbers: check those first.

Common faults in this build

LED never lights: what should I check?

Zener is backwards. The band must face the + rail.

All LEDs always on: what should I check?

Zeners are shorted or missing from the series path.

LED too dim: what should I check?

The supply is only just above the step. Raise it or use a lower resistor.

Steps are in the wrong places: what should I check?

Check the zener values printed on the parts.