Fault finder: Pressure pad door chime

6 checks for this build on the Nano. Work from the top: power first, then each part, then the code.

0 of 6 checked
Power🔧 DC volts, 20 V rangeCheck 1 of 6

Nano supply pin

Plug the Nano into USB. Black probe on a GND pin, red probe on the 5V pin of the board.

You should see: 4.6 to 5.3 V

V

Readings are compared with the ranges for this build's parts. A meter on the wrong range or a loose probe gives odd numbers: check those first.

Common faults in this build

Always chimes: what should I check?

Raise THRESHOLD or check the 10 kilohm resistor is to GND.

Never chimes: what should I check?

Lower THRESHOLD and check the FSR legs are in the right rows.

Readings jump around: what should I check?

Add a 100 nanofarad capacitor from A0 to GND.

Buzzer stays on: what should I check?

Check its wiring and that it is an active buzzer.

Pad stops working: what should I check?

The thin legs may have been bent, replace the sensor.