Fault finder: Fodder silo level meter
11 checks for this build on the Nano. Work from the top: power first, then each part, then the code.
0 of 11 checked
Power🔧 DC volts, 20 V rangeCheck 1 of 11
Nano supply pin
Plug the Nano into USB. Black probe on a GND pin, red probe on the 5V pin of the board.
You should see: 4.6 to 5.3 V
Readings are compared with the ranges for this build's parts. A meter on the wrong range or a loose probe gives odd numbers: check those first.
Common faults in this build
Reads 8190: what should I check?
Nothing in range or the sensor is blinded by dust. Clean and recalibrate.
Reading jumps: what should I check?
The surface is uneven. Aim at the pile centre and use the median.
Percentage backwards: what should I check?
You swapped e and f. Save them again.
Screen blank: what should I check?
Check the I2C address and wiring.