Fault finder: Fodder silo level meter

11 checks for this build on the Nano. Work from the top: power first, then each part, then the code.

0 of 11 checked
Power🔧 DC volts, 20 V rangeCheck 1 of 11

Nano supply pin

Plug the Nano into USB. Black probe on a GND pin, red probe on the 5V pin of the board.

You should see: 4.6 to 5.3 V

V

Readings are compared with the ranges for this build's parts. A meter on the wrong range or a loose probe gives odd numbers: check those first.

Common faults in this build

Reads 8190: what should I check?

Nothing in range or the sensor is blinded by dust. Clean and recalibrate.

Reading jumps: what should I check?

The surface is uneven. Aim at the pile centre and use the median.

Percentage backwards: what should I check?

You swapped e and f. Save them again.

Screen blank: what should I check?

Check the I2C address and wiring.