Fault finder: Floating input and pull-up lab

9 checks for this build on the Nano. Work from the top: power first, then each part, then the code.

0 of 9 checked
Power🔧 DC volts, 20 V rangeCheck 1 of 9

Nano supply pin

Plug the Nano into USB. Black probe on a GND pin, red probe on the 5V pin of the board.

You should see: 4.6 to 5.3 V

V

Readings are compared with the ranges for this build's parts. A meter on the wrong range or a loose probe gives odd numbers: check those first.

Common faults in this build

Counts never change: what should I check?

Check the wire is in D2 and the code is in the right mode.

Floating reading looks steady: what should I check?

Touch the wire with a finger, it picks up more noise.

LED always off: what should I check?

Check its direction and that the LED is on D6.

Pressed shows no change: what should I check?

Check which side of the button goes to 5V or GND.

Monitor shows nothing: what should I check?

Set 9600 baud.