Fault finder: Drip irrigation timer with zones

10 checks for this build on the Nano. Work from the top: power first, then each part, then the code.

0 of 10 checked
Power🔧 DC volts, 20 V rangeCheck 1 of 10

Nano supply pin

Plug the Nano into USB. Black probe on a GND pin, red probe on the 5V pin of the board.

You should see: 4.6 to 5.3 V

V

Readings are compared with the ranges for this build's parts. A meter on the wrong range or a loose probe gives odd numbers: check those first.

Common faults in this build

Relay does not click: what should I check?

Check the logic (ACTIVE_LOW) and the 5 V supply.

Valve does not open: what should I check?

Check the 12 V on the COM terminal and the NO wiring.

Nano resets: what should I check?

Check the flyback diodes and the buck output.

Wrong time: what should I check?

Set the RTC again and check the battery on it.