Fault finder: Drip irrigation timer with zones
10 checks for this build on the Nano. Work from the top: power first, then each part, then the code.
0 of 10 checked
Power🔧 DC volts, 20 V rangeCheck 1 of 10
Nano supply pin
Plug the Nano into USB. Black probe on a GND pin, red probe on the 5V pin of the board.
You should see: 4.6 to 5.3 V
Readings are compared with the ranges for this build's parts. A meter on the wrong range or a loose probe gives odd numbers: check those first.
Common faults in this build
Relay does not click: what should I check?
Check the logic (ACTIVE_LOW) and the 5 V supply.
Valve does not open: what should I check?
Check the 12 V on the COM terminal and the NO wiring.
Nano resets: what should I check?
Check the flyback diodes and the buck output.
Wrong time: what should I check?
Set the RTC again and check the battery on it.