Fault finder: Capacitance meter
6 checks for this build on the Uno. Work from the top: power first, then each part, then the code.
0 of 6 checked
Power🔧 DC volts, 20 V rangeCheck 1 of 6
Uno supply pin
Plug the Uno into USB. Black probe on a GND pin, red probe on the 5V pin of the board.
You should see: 4.6 to 5.3 V
Readings are compared with the ranges for this build's parts. A meter on the wrong range or a loose probe gives odd numbers: check those first.
Common faults in this build
The LCD is blank: what should I check?
Turn the contrast trimmer on the backpack, and try address 0x3F.
Readings are always about 5 to 10 % off: what should I check?
Measure the 10 kΩ resistor with a multimeter and put the real value in R_CHARGE.
Small capacitors read nonsense: what should I check?
Under 1 µF the charge time is only microseconds. This build is for larger values.
It never finishes: what should I check?
The capacitor may be leaky or a very large value. The sketch gives up after 20 seconds.