Fault finder: Smart cane for blind users
7 checks for this build on the Nano. Work from the top: power first, then each part, then the code.
0 of 7 checked
Power🔧 DC volts, 20 V rangeCheck 1 of 7
Nano supply pin
Plug the Nano into USB. Black probe on a GND pin, red probe on the 5V pin of the board.
You should see: 4.6 to 5.3 V
Readings are compared with the ranges for this build's parts. A meter on the wrong range or a loose probe gives odd numbers: check those first.
Common faults in this build
Constant vibration: what should I check?
Sensors seeing each other or a cane edge; adjust the angle.
No vibration: what should I check?
Check the transistor pins (E, B, C) and diode direction.
Nano resets when motors start: what should I check?
Boost module too weak or loose wire; add a 100 uF capacitor on 5 V.
Readings jump: what should I check?
Soft objects and angles confuse ultrasound.
Cell drains quickly: what should I check?
Motors at full strength; lower MAX_PWM.