Fault finder: Reverse polarity protection demo
7 checks for this build on the board. Work from the top: power first, then each part, then the code.
0 of 7 checked
Power🔧 DC volts, 20 V rangeCheck 1 of 7
board supply pin
Plug the board into USB. Black probe on a GND pin, red probe on the 5V pin of the board.
You should see: 4.6 to 5.3 V
Readings are compared with the ranges for this build's parts. A meter on the wrong range or a loose probe gives odd numbers: check those first.
Common faults in this build
LED never lights: what should I check?
The diode may be the wrong way round, check the stripe.
LED very dim: what should I check?
Check the resistor value and the battery voltage.
Diode drop reads zero: what should I check?
The meter probes are on the wrong points.
Diode warm: what should I check?
The load current is too high, check the resistor.
Reversed battery lit the LED: what should I check?
The diode is not in series with the battery, rebuild it.