Tools / Wheatstone bridge balance
How to balance a Wheatstone bridge and find an unknown resistor
A bridge compares two voltage dividers. When their middle points match, the output is zero, which is a very sensitive way to measure a small change.
Rx = R2 × R3 ÷ R1 at balance; Vout = Vs × (Rx ÷ (R3 + Rx) − R2 ÷ (R1 + R2))
Result
- Balance rx
- 1 kΩ
- Left node
- 2.5 V
- Right node
- 2.561 V
- Bridge output
- 60.98 mV
- Imbalance
- 5 %
Step by step
The working with your numbers
- Left divider (R1 on top, R2 below)
VA = Vs × R2 ÷ (R1 + R2) = 5 × 1,000 ÷ (1,000 + 1,000) = 2.5 V - Right divider (R3 on top, Rx below)
VB = Vs × Rx ÷ (R3 + Rx) = 5 × 1,050 ÷ (1,000 + 1,050) = 2.56 V - Bridge output
Vout = VB − VA = 61 mV - Rx that makes the output zero
Rx = R2 × R3 ÷ R1 = 1,000 × 1,000 ÷ 1,000 = 1 kΩBalance means VA = VB, which gives R2 ÷ R1 = Rx ÷ R3.
Does the answer make sense?
- OK: Off balance by 5 %. A bridge turns that small difference into a voltage you can amplify.
- OK: Sensitivity: near balance with all four arms equal, the output is about Vs ÷ 4 for each 100 % change in one arm, so a 1 % change gives about 12.5 mV.
Common mistakes
- Mixing up which resistor is the unknown arm. Rx is the lower right one here, so Rx = R2 × R3 ÷ R1.
- Measuring the output with a meter that loads the bridge. Use a high-impedance input or an amplifier.
- Ignoring lead resistance when the sensor is far away: it adds to the arm you are measuring.
Learn it, try it, build it
Calculated, not measured. Check the exact part datasheet and your real circuit before powering anything.
Common questions
What is the balance condition of a Wheatstone bridge?
R1 ÷ R2 = R3 ÷ Rx, so Rx = R2 × R3 ÷ R1. When this holds, the two midpoints are at the same voltage and the galvanometer reads zero.
Why use a bridge for strain gauges and thermistors?
These sensors change by a tiny fraction of their resistance. A bridge cancels the large constant part and leaves only the change, which is then easy to amplify.