Tools / First-order Bode point

How to read a first-order Bode plot at a frequency

A Bode plot shows gain and phase against frequency on log axes. A first-order system is flat, then falls 20 dB for every tenfold rise in frequency.

|H| = H0 − 10 log10(1 + (f ÷ fp)²) dB; φ = −arctan(f ÷ fp)

Inputs

dB
Hz
Hz

Results update as you type. Prefixes work: 4.7k, 100u, 10n.

Result
Gain (dB)
19.96
Phase (°)
-84.29
Straight line (dB)
20
Error (dB)
-0.04321
Unity gain
99.99 kHz
Step by step

The working with your numbers

  1. How far above the pole you aref ÷ fp = 10 kHz ÷ 1 kHz = 10
  2. Exact gaingain = 40 dB − 10 × log10(1 + 10²) = 19.96 dB|H| = H0 ÷ √(1 + (f ÷ fp)²), written in decibels.
  3. Phaseφ = −arctan(10) = −84.29°Zero at low frequency, −45° at the pole, tending to −90° far above it.
  4. Straight-line (Bode) approximation40 − 20 × log10(10) = 20 dB above the poleThe real curve differs by −0.0432 dB here. The biggest difference is −3 dB, exactly at the pole.

Does the answer make sense?

  • OK: Within a decade of the pole, where the straight-line approximation is least accurate and the phase is changing fastest.
  • OK: A gain of 40 dB is a voltage ratio of 100.

Common mistakes

  • Using 10 × log10 for voltage ratios. For voltage use 20 × log10; 10 × log10 is for power.
  • Reading the −3 dB point as the point where the gain is half. It is 0.707 of the voltage, half of the power.
  • Forgetting that the phase is already −45° at the pole, not at the frequency where the gain is lost.

Learn it, try it, build it

Calculated, not measured. Check the exact part datasheet and your real circuit before powering anything.

Common questions

What is the slope of a first-order Bode plot?

−20 dB per decade (about −6 dB per octave) above the pole frequency, and flat below it. The phase falls from 0° to −90°, passing through −45° at the pole.

How do you convert a gain in dB to a ratio?

For voltage, ratio = 10^(dB ÷ 20). So 20 dB is 10×, 40 dB is 100× and −3 dB is about 0.71×.