Fault finder: Vermicompost bin moisture keeper

11 checks for this build on the Nano. Work from the top: power first, then each part, then the code.

0 of 11 checked
Power🔧 DC volts, 20 V rangeCheck 1 of 11

Nano supply pin

Plug the Nano into USB. Black probe on a GND pin, red probe on the 5V pin of the board.

You should see: 4.6 to 5.3 V

V

Readings are compared with the ranges for this build's parts. A meter on the wrong range or a loose probe gives odd numbers: check those first.

Common faults in this build

Pump never runs: what should I check?

Check the relay wiring and that it clicks when you lower DRY_RAW.

Pump runs but no water: what should I check?

Tube kinked or the pump is dry. Prime it.

Over-watering: what should I check?

Increase the wait or shorten the spray.

Sensor reads strangely: what should I check?

The board's coating must be intact and only the probe tip in the bedding.