Fault finder: Water level indicator
10 checks for this build on the Uno. Work from the top: power first, then each part, then the code.
0 of 10 checked
Power🔧 DC volts, 20 V rangeCheck 1 of 10
Uno supply pin
Plug the Uno into USB. Black probe on a GND pin, red probe on the 5V pin of the board.
You should see: 4.6 to 5.3 V
Readings are compared with the ranges for this build's parts. A meter on the wrong range or a loose probe gives odd numbers: check those first.
Common faults in this build
Readings drift over days: what should I check?
Corrosion: make sure the sensor is only powered while reading.
Never reaches FULL: what should I check?
Your strip is shorter than the water rise: lower FULL.
Readings at 0 when wet: what should I check?
The + wire is not on D7, or D7 is never set HIGH.