Fault finder: Water leak detector with phone alert
8 checks for this build on the ESP32. Work from the top: power first, then each part, then the code.
0 of 8 checked
Power🔧 DC volts, 20 V rangeCheck 1 of 8
ESP32 supply pin
Plug the ESP32 into USB. Black probe on a GND pin, red probe on the 3V3 pin of the board.
You should see: 3.15 to 3.45 V
Readings are compared with the ranges for this build's parts. A meter on the wrong range or a loose probe gives odd numbers: check those first.
Common faults in this build
No phone alert: what should I check?
Wi-Fi did not connect, or the topic name differs between app and code.
Reading never changes: what should I check?
Check the sensor is powered through GPIO 4 and signal on GPIO 3.
Strip corrodes: what should I check?
It was powered all the time. Keep the pulsed power as in the code.
False alarms: what should I check?
Humidity or dust. Raise the threshold slightly.