Fault finder: Ultrasonic tape measure
9 checks for this build on the Uno. Work from the top: power first, then each part, then the code.
0 of 9 checked
Power🔧 DC volts, 20 V rangeCheck 1 of 9
Uno supply pin
Plug the Uno into USB. Black probe on a GND pin, red probe on the 5V pin of the board.
You should see: 4.6 to 5.3 V
Readings are compared with the ranges for this build's parts. A meter on the wrong range or a loose probe gives odd numbers: check those first.
Common faults in this build
Always out of range: what should I check?
Check Trig and Echo are not swapped and the sensor has 5 V.
Reading jumps around: what should I check?
Hold the sensor steady and aim at a flat, hard surface.
Screen blank: what should I check?
Try address 0x3F, or turn the contrast screw on the back.
All readings a few percent off: what should I check?
Set AIR_TEMP_C to the real air temperature.
Minimum distance wrong: what should I check?
The sensor cannot measure under about 2 cm.