Fault finder: Ultrasonic distance display
11 checks for this build on the Uno. Work from the top: power first, then each part, then the code.
0 of 11 checked
Power🔧 DC volts, 20 V rangeCheck 1 of 11
Uno supply pin
Plug the Uno into USB. Black probe on a GND pin, red probe on the 5V pin of the board.
You should see: 4.6 to 5.3 V
Readings are compared with the ranges for this build's parts. A meter on the wrong range or a loose probe gives odd numbers: check those first.
Common faults in this build
Always "Out of range: what should I check?
Trig and Echo swapped, or soft surfaces absorbing the sound.
Row of blocks on LCD: what should I check?
Turn the contrast trimmer.
Jumpy readings: what should I check?
Take the median of 3 readings.