Fault finder: VOC and eCO2 desk sensor
9 checks for this build on the ESP32. Work from the top: power first, then each part, then the code.
0 of 9 checked
Power🔧 DC volts, 20 V rangeCheck 1 of 9
ESP32 supply pin
Plug the ESP32 into USB. Black probe on a GND pin, red probe on the 3V3 pin of the board.
You should see: 3.15 to 3.45 V
Readings are compared with the ranges for this build's parts. A meter on the wrong range or a loose probe gives odd numbers: check those first.
Common faults in this build
ENS160 not found: what should I check?
Check the address (0x52 or 0x53 depending on the breakout) and wiring.
Readings stuck at the first values: what should I check?
Still in the first warm-up. Wait.
eCO2 drifts at night: what should I check?
This is normal for an estimate. Treat the trend, not the number.
Compile errors on ens160 functions: what should I check?
The library version differs. Match the code to its bundled example.