Fault finder: Touchless soap and sanitiser dispenser
7 checks for this build on the Nano. Work from the top: power first, then each part, then the code.
0 of 7 checked
Power🔧 DC volts, 20 V rangeCheck 1 of 7
Nano supply pin
Plug the Nano into USB. Black probe on a GND pin, red probe on the 5V pin of the board.
You should see: 4.6 to 5.3 V
Readings are compared with the ranges for this build's parts. A meter on the wrong range or a loose probe gives odd numbers: check those first.
Common faults in this build
Pump runs all the time: what should I check?
Check the gate pull-down and the MOSFET pins (gate, drain, source).
Does not trigger: what should I check?
Adjust the sensor range screw and check D2.
Dose too big or small: what should I check?
Change DOSE_MS.
Dripping: what should I check?
Fit a small loop in the tube above the nozzle.