Fault finder: Touchless soap and sanitiser dispenser

7 checks for this build on the Nano. Work from the top: power first, then each part, then the code.

0 of 7 checked
Power🔧 DC volts, 20 V rangeCheck 1 of 7

Nano supply pin

Plug the Nano into USB. Black probe on a GND pin, red probe on the 5V pin of the board.

You should see: 4.6 to 5.3 V

V

Readings are compared with the ranges for this build's parts. A meter on the wrong range or a loose probe gives odd numbers: check those first.

Common faults in this build

Pump runs all the time: what should I check?

Check the gate pull-down and the MOSFET pins (gate, drain, source).

Does not trigger: what should I check?

Adjust the sensor range screw and check D2.

Dose too big or small: what should I check?

Change DOSE_MS.

Dripping: what should I check?

Fit a small loop in the tube above the nozzle.