Fault finder: Touch-contact hit lights
8 checks for this build on the Nano. Work from the top: power first, then each part, then the code.
0 of 8 checked
Power🔧 DC volts, 20 V rangeCheck 1 of 8
Nano supply pin
Plug the Nano into USB. Black probe on a GND pin, red probe on the 5V pin of the board.
You should see: 4.6 to 5.3 V
Readings are compared with the ranges for this build's parts. A meter on the wrong range or a loose probe gives odd numbers: check those first.
Common faults in this build
Scores with no touch: what should I check?
Keep the pad wires apart and check for loose strands.
No score on touch: what should I check?
Press the foil flat and check the tip lead goes to GND.
Both score together: what should I check?
The two pads are touching each other.
No beep: what should I check?
Check the buzzer is the active type and the plus wire is on D8.
Serial shows nothing: what should I check?
Set 9600 baud in the monitor.