Fault finder: Cloud weather logger with ThingSpeak

5 checks for this build on the board. Work from the top: power first, then each part, then the code.

0 of 5 checked
Power🔧 DC volts, 20 V rangeCheck 1 of 5

board supply pin

Plug the board into USB. Black probe on a GND pin, red probe on the 5V pin of the board.

You should see: 4.6 to 5.3 V

V

Readings are compared with the ranges for this build's parts. A meter on the wrong range or a loose probe gives odd numbers: check those first.

Common faults in this build

HTTP 200 but entry 0: what should I check?

Updates came faster than 15 s or the key is wrong. Use the Write key, not the Read key.

DHT read failed: what should I check?

Check DATA is on D4 and give the sensor 2 s between reads.

Negative HTTP code: what should I check?

No internet. Check the router and that the network is 2.4 GHz.

Keep the key private: what should I check?

Anyone with the Write key can post to your channel. Do not share the sketch with the key in it.