Fault finder: Tank fill control with float switches
8 checks for this build on the Nano. Work from the top: power first, then each part, then the code.
0 of 8 checked
Power🔧 DC volts, 20 V rangeCheck 1 of 8
Nano supply pin
Plug the Nano into USB. Black probe on a GND pin, red probe on the 5V pin of the board.
You should see: 4.6 to 5.3 V
Readings are compared with the ranges for this build's parts. A meter on the wrong range or a loose probe gives odd numbers: check those first.
Common faults in this build
Pump never starts: what should I check?
Check the float contact direction and the relay polarity.
Chatters: what should I check?
Raise the low float further below the high one.
Relay clicks but the pump is dead: what should I check?
Check the pump fuse and wiring.
Alarm on start: what should I check?
Reset the board after fixing the fault.