Fault finder: Switch bounce and debounce lab
10 checks for this build on the board. Work from the top: power first, then each part, then the code.
0 of 10 checked
Power🔧 DC volts, 20 V rangeCheck 1 of 10
board supply pin
Plug the board into USB. Black probe on a GND pin, red probe on the 5V pin of the board.
You should see: 4.6 to 5.3 V
Readings are compared with the ranges for this build's parts. A meter on the wrong range or a loose probe gives odd numbers: check those first.
Common faults in this build
All sources count too fast: what should I check?
A floating pin (a pull-up missing or an unused input untied). Tie unused inputs to GND.
Counter does not reset: what should I check?
CLR must go high briefly. Check the reset button and the 10 kΩ to GND.
RC stage is slow to respond: what should I check?
10 kΩ with 10 µF is 100 ms. Use a smaller capacitor for a quicker feel.
Latch counts on RESET: what should I check?
The outputs of the NAND gates are crossed wrongly. Re-check pins 2, 3, 5 and 6.