Fault finder: Solar water pump dry-run protector

8 checks for this build on the Nano. Work from the top: power first, then each part, then the code.

0 of 8 checked
Power🔧 DC volts, 20 V rangeCheck 1 of 8

Nano supply pin

Plug the Nano into USB. Black probe on a GND pin, red probe on the 5V pin of the board.

You should see: 4.6 to 5.3 V

V

Readings are compared with the ranges for this build's parts. A meter on the wrong range or a loose probe gives odd numbers: check those first.

Common faults in this build

Current reads about zero with the pump on: what should I check?

Check the sensor is in series and wired correctly.

Pump stops while pumping: what should I check?

LOW_AMPS is too high; lower it.

Reading drifts: what should I check?

Recalibrate the zero with the pump off.

Relay chatters: what should I check?

Check the supply voltage with the pump running.