Power🔧 DC volts, 20 V rangeCheck 1 of 9

Nano supply pin

Plug the Nano into USB. Black probe on a GND pin, red probe on the 5V pin of the board.

You should see: 4.6 to 5.3 V

V

Readings are compared with the ranges for this build's parts. A meter on the wrong range or a loose probe gives odd numbers: check those first.

Common faults in this build

Only zeros logged: what should I check?

The SD card did not start. Check FAT32 and wiring.

Reads -127: what should I check?

A probe or the pull-up is loose.

Depths mixed up: what should I check?

Warm each probe and fix the ORDER table.

Time stamps wrong: what should I check?

Set the DS3231 and check its coin cell.