Fault finder: Three pot moisture lights
9 checks for this build on the Nano. Work from the top: power first, then each part, then the code.
0 of 9 checked
Power🔧 DC volts, 20 V rangeCheck 1 of 9
Nano supply pin
Plug the Nano into USB. Black probe on a GND pin, red probe on the 5V pin of the board.
You should see: 4.6 to 5.3 V
Readings are compared with the ranges for this build's parts. A meter on the wrong range or a loose probe gives odd numbers: check those first.
Common faults in this build
All the same reading: what should I check?
Check the output wires on A0, A1, A2.
Reading never changes: what should I check?
Check the power and ground wires.
LEDs the wrong way round: what should I check?
Swap DRY and WET or check the module type.
Numbers jump: what should I check?
Keep the wires short and away from the LEDs.
Probe stops working: what should I check?
Water got into the electronics, keep it above the line.