Fault finder: Soil moisture traffic light
9 checks for this build on the Nano. Work from the top: power first, then each part, then the code.
0 of 9 checked
Power🔧 DC volts, 20 V rangeCheck 1 of 9
Nano supply pin
Plug the Nano into USB. Black probe on a GND pin, red probe on the 5V pin of the board.
You should see: 4.6 to 5.3 V
Readings are compared with the ranges for this build's parts. A meter on the wrong range or a loose probe gives odd numbers: check those first.
Common faults in this build
Percentage stuck at 0 or 100: what should I check?
Re-measure AIR_VALUE and WATER_VALUE.
Readings noisy: what should I check?
Keep wires short and away from motors.
Wrong LED lights: what should I check?
Check the LED legs and the pin numbers.
Probe gives odd readings: what should I check?
Check it is a capacitive probe and not a resistive one.
Readings drift over days: what should I check?
Soil temperature and packing change readings, recheck now and then.