Projects / Smart cat fountain / Fault finder

Fault finder: Smart cat fountain

10 checks for this build on the ESP32. Work from the top: power first, then each part, then the code.

0 of 10 checked
Power🔧 DC volts, 20 V rangeCheck 1 of 10

ESP32 supply pin

Plug the ESP32 into USB. Black probe on a GND pin, red probe on the 3V3 pin of the board.

You should see: 3.15 to 3.45 V

V

Readings are compared with the ranges for this build's parts. A meter on the wrong range or a loose probe gives odd numbers: check those first.

Common faults in this build

Pump never starts: what should I check?

Check the MOSFET orientation and the level sensor output.

Always low water: what should I check?

Move the sensor to the right height on the tank wall.

False visits: what should I check?

Aim the PIR away from windows.

No alert: what should I check?

Check the Wi-Fi details and webhook address.