Fault finder: Two-point sensor calibration
7 checks for this build on the Nano. Work from the top: power first, then each part, then the code.
0 of 7 checked
Power🔧 DC volts, 20 V rangeCheck 1 of 7
Nano supply pin
Plug the Nano into USB. Black probe on a GND pin, red probe on the 5V pin of the board.
You should see: 4.6 to 5.3 V
Readings are compared with the ranges for this build's parts. A meter on the wrong range or a loose probe gives odd numbers: check those first.
Common faults in this build
DS18B20 reads -127: what should I check?
Check the 4.7 kΩ pull-up and wiring.
TMP36 noisy: what should I check?
Averaging is in the code; add a 100 nF capacitor on the output.
Corrected is worse: what should I check?
Check RAW and REF values are not swapped.
Water short circuit: what should I check?
Keep the sensors sealed in a bag.