Fault finder: Lift overload alarm model

8 checks for this build on the Nano. Work from the top: power first, then each part, then the code.

0 of 8 checked
Power🔧 DC volts, 20 V rangeCheck 1 of 8

Nano supply pin

Plug the Nano into USB. Black probe on a GND pin, red probe on the 5V pin of the board.

You should see: 4.6 to 5.3 V

V

Readings are compared with the ranges for this build's parts. A meter on the wrong range or a loose probe gives odd numbers: check those first.

Common faults in this build

Negative readings: what should I check?

Swap the signal wires A+ and A-.

Drifting reading: what should I check?

Let the board warm up and keep the load cell still.

Wrong weight: what should I check?

Recalibrate CAL with a known weight.

No reading: what should I check?

Check DT and SCK pins and the 5 V supply.