Fault finder: Lift overload alarm model
8 checks for this build on the Nano. Work from the top: power first, then each part, then the code.
0 of 8 checked
Power🔧 DC volts, 20 V rangeCheck 1 of 8
Nano supply pin
Plug the Nano into USB. Black probe on a GND pin, red probe on the 5V pin of the board.
You should see: 4.6 to 5.3 V
Readings are compared with the ranges for this build's parts. A meter on the wrong range or a loose probe gives odd numbers: check those first.
Common faults in this build
Negative readings: what should I check?
Swap the signal wires A+ and A-.
Drifting reading: what should I check?
Let the board warm up and keep the load cell still.
Wrong weight: what should I check?
Recalibrate CAL with a known weight.
No reading: what should I check?
Check DT and SCK pins and the 5 V supply.