Fault finder: RS-485 multi-drop sensor network
7 checks for this build on the Nano. Work from the top: power first, then each part, then the code.
0 of 7 checked
Power🔧 DC volts, 20 V rangeCheck 1 of 7
Nano supply pin
Plug the Nano into USB. Black probe on a GND pin, red probe on the 5V pin of the board.
You should see: 4.6 to 5.3 V
Readings are compared with the ranges for this build's parts. A meter on the wrong range or a loose probe gives odd numbers: check those first.
Common faults in this build
No answer: what should I check?
Check DE and RE are tied to D3 and A and B are not swapped.
Bad checksum: what should I check?
Check both ends use the same baud rate and keep wires twisted.
Two nodes answer together: what should I check?
Check each slave has a different address.
DHT reads nan: what should I check?
Check the 10 kΩ pull-up on its data line.