Fault finder: RS-485 multi-drop sensor network

7 checks for this build on the Nano. Work from the top: power first, then each part, then the code.

0 of 7 checked
Power🔧 DC volts, 20 V rangeCheck 1 of 7

Nano supply pin

Plug the Nano into USB. Black probe on a GND pin, red probe on the 5V pin of the board.

You should see: 4.6 to 5.3 V

V

Readings are compared with the ranges for this build's parts. A meter on the wrong range or a loose probe gives odd numbers: check those first.

Common faults in this build

No answer: what should I check?

Check DE and RE are tied to D3 and A and B are not swapped.

Bad checksum: what should I check?

Check both ends use the same baud rate and keep wires twisted.

Two nodes answer together: what should I check?

Check each slave has a different address.

DHT reads nan: what should I check?

Check the 10 kΩ pull-up on its data line.