Fault finder: Rotary encoder settings box
11 checks for this build on the Nano. Work from the top: power first, then each part, then the code.
0 of 11 checked
Power🔧 DC volts, 20 V rangeCheck 1 of 11
Nano supply pin
Plug the Nano into USB. Black probe on a GND pin, red probe on the 5V pin of the board.
You should see: 4.6 to 5.3 V
Readings are compared with the ranges for this build's parts. A meter on the wrong range or a loose probe gives odd numbers: check those first.
Common faults in this build
Menu moves the wrong way: what should I check?
Swap the CLK and DT wires, or change the sign in onTurn.
Steps skip or double: what should I check?
Increase the 2 ms bounce limit, or add a 10 nanofarad capacitor from CLK to GND.
Display blank: what should I check?
Try address 0x3D, and check the display voltage.
Settings do not survive power-off: what should I check?
Check saveSettings is called when you press the knob to finish editing.
LED never lights: what should I check?
Check the LED direction and that brightness is above 0.