Fault finder: RO water purifier filter life counter

7 checks for this build on the Nano. Work from the top: power first, then each part, then the code.

0 of 7 checked
Power🔧 DC volts, 20 V rangeCheck 1 of 7

Nano supply pin

Plug the Nano into USB. Black probe on a GND pin, red probe on the 5V pin of the board.

You should see: 4.6 to 5.3 V

V

Readings are compared with the ranges for this build's parts. A meter on the wrong range or a loose probe gives odd numbers: check those first.

Common faults in this build

Count stays zero: what should I check?

Flow is too low; fit it where flow is higher.

Count too high or low: what should I check?

Adjust PULSES_PER_L with a jug.

TDS jumps: what should I check?

Keep the probe still and out of air bubbles.