Fault finder: Rain on the clothes line alert

10 checks for this build on the Nano. Work from the top: power first, then each part, then the code.

0 of 10 checked
Power🔧 DC volts, 20 V rangeCheck 1 of 10

Nano supply pin

Plug the Nano into USB. Black probe on a GND pin, red probe on the 5V pin of the board.

You should see: 4.6 to 5.3 V

V

Readings are compared with the ranges for this build's parts. A meter on the wrong range or a loose probe gives odd numbers: check those first.

Common faults in this build

Reads low when dry: what should I check?

Humid air or a dirty plate, raise the WET_BELOW threshold.

Never alarms: what should I check?

Lower the check time or check the AO wire.

Alarm triggers in dew: what should I check?

Raise NEEDED to 5 readings.

Plate tracks look dark: what should I check?

Corrosion, clean it and shorten the on time.

Buzzer silent: what should I check?

Check it is an active buzzer on D6.