Fault finder: Power outage SMS alert
6 checks for this build on the Nano. Work from the top: power first, then each part, then the code.
0 of 6 checked
Power🔧 DC volts, 20 V rangeCheck 1 of 6
Nano supply pin
Plug the Nano into USB. Black probe on a GND pin, red probe on the 5V pin of the board.
You should see: 4.6 to 5.3 V
Readings are compared with the ranges for this build's parts. A meter on the wrong range or a loose probe gives odd numbers: check those first.
Common faults in this build
No SMS arrives: what should I check?
Check the SIM has credit and signal, and that AT+CSQ in the monitor shows 10 or more.
The module keeps restarting: what should I check?
The supply sags when it transmits, so check the 1000 uF capacitor and use the cell, not the Nano 5V pin.
Reading stays at 0 with the adapter on: what should I check?
Check the 10 k divider is joined to the adapter output and to ground.
Garbled text from the module: what should I check?
Check the baud rate is 9600 and the module ground joins the Nano ground.
The Nano resets when the unplug happens: what should I check?
The MT3608 may be set below 5 V, so reset it to 5.0 V.