Projects / PNP dark detector / Fault finder

Fault finder: PNP dark detector

11 checks for this build on the board. Work from the top: power first, then each part, then the code.

0 of 11 checked
Power🔧 DC volts, 20 V rangeCheck 1 of 11

board supply pin

Plug the board into USB. Black probe on a GND pin, red probe on the 5V pin of the board.

You should see: 4.6 to 5.3 V

V

Readings are compared with the ranges for this build's parts. A meter on the wrong range or a loose probe gives odd numbers: check those first.

Common faults in this build

LED never lights: what should I check?

Check the pinout, the LED direction and the pot is not at its lowest with a very bright room.

LED always on: what should I check?

The LDR may be disconnected or the pot is at maximum with a dim room.

LED dim even when covered: what should I check?

Check the 1 kilohm value and the battery voltage.

Transistor gets hot: what should I check?

Check the collector resistor is in series with the LED.

Switching point too sensitive: what should I check?

Raise the lower resistance with the pot.