Fault finder: Plant soil moisture logger

9 checks for this build on the ESP32. Work from the top: power first, then each part, then the code.

0 of 9 checked
Power🔧 DC volts, 20 V rangeCheck 1 of 9

ESP32 supply pin

Plug the ESP32 into USB. Black probe on a GND pin, red probe on the 3V3 pin of the board.

You should see: 3.15 to 3.45 V

V

Readings are compared with the ranges for this build's parts. A meter on the wrong range or a loose probe gives odd numbers: check those first.

Common faults in this build

raw stays at 0 or 4095: what should I check?

Check AOUT is on GPIO34 and the sensor has 3V3. Do not use ADC2 pins with Wi-Fi.

Percent goes the wrong way: what should I check?

DRY and WET are swapped in the code.

Readings drift over days: what should I check?

Normal for cheap sensors; recalibrate monthly and keep the top dry.