Fault finder: Pill bottle open logger

11 checks for this build on the Nano. Work from the top: power first, then each part, then the code.

0 of 11 checked
Power🔧 DC volts, 20 V rangeCheck 1 of 11

Nano supply pin

Plug the Nano into USB. Black probe on a GND pin, red probe on the 5V pin of the board.

You should see: 4.6 to 5.3 V

V

Readings are compared with the ranges for this build's parts. A meter on the wrong range or a loose probe gives odd numbers: check those first.

Common faults in this build

Opening not counted: what should I check?

Keep the cap off for at least a second and check D2.

Counts when the cap is on: what should I check?

The reed does not close, move the magnet closer.

Wrong time: what should I check?

Reflash once with the computer clock correct.

Blank screen: what should I check?

Check A4 and A5 and the OLED address.

Log empty after power-off: what should I check?

The EEPROM needs a first opening to be saved.