Fault finder: Pill bottle open logger
11 checks for this build on the Nano. Work from the top: power first, then each part, then the code.
0 of 11 checked
Power🔧 DC volts, 20 V rangeCheck 1 of 11
Nano supply pin
Plug the Nano into USB. Black probe on a GND pin, red probe on the 5V pin of the board.
You should see: 4.6 to 5.3 V
Readings are compared with the ranges for this build's parts. A meter on the wrong range or a loose probe gives odd numbers: check those first.
Common faults in this build
Opening not counted: what should I check?
Keep the cap off for at least a second and check D2.
Counts when the cap is on: what should I check?
The reed does not close, move the magnet closer.
Wrong time: what should I check?
Reflash once with the computer clock correct.
Blank screen: what should I check?
Check A4 and A5 and the OLED address.
Log empty after power-off: what should I check?
The EEPROM needs a first opening to be saved.