Fault finder: Pico stepper gauge dial

7 checks for this build on the Pico. Work from the top: power first, then each part, then the code.

0 of 7 checked
Power🔧 DC volts, 20 V rangeCheck 1 of 7

Pico supply pin

Plug the Pico into USB. Black probe on a GND pin, red probe on the 3V3(OUT) pin of the board.

You should see: 3.15 to 3.45 V

V

Readings are compared with the ranges for this build's parts. A meter on the wrong range or a loose probe gives odd numbers: check those first.

Common faults in this build

Motor shakes but does not turn: what should I check?

Check the four wires are in order IN1 to IN4 and the plug is fully in.

Skips steps: what should I check?

Raise the 3 millisecond pause, for example to 5.

Needle drifts away from the scale: what should I check?

Steps were lost, power off, reset the needle by hand and restart.

Motor gets hot: what should I check?

Check the program releases the coils when it arrives.

Jitters at rest: what should I check?

Increase the DEADBAND.