Fault finder: Pico stepper gauge dial
7 checks for this build on the Pico. Work from the top: power first, then each part, then the code.
0 of 7 checked
Power🔧 DC volts, 20 V rangeCheck 1 of 7
Pico supply pin
Plug the Pico into USB. Black probe on a GND pin, red probe on the 3V3(OUT) pin of the board.
You should see: 3.15 to 3.45 V
Readings are compared with the ranges for this build's parts. A meter on the wrong range or a loose probe gives odd numbers: check those first.
Common faults in this build
Motor shakes but does not turn: what should I check?
Check the four wires are in order IN1 to IN4 and the plug is fully in.
Skips steps: what should I check?
Raise the 3 millisecond pause, for example to 5.
Needle drifts away from the scale: what should I check?
Steps were lost, power off, reset the needle by hand and restart.
Motor gets hot: what should I check?
Check the program releases the coils when it arrives.
Jitters at rest: what should I check?
Increase the DEADBAND.