Fault finder: Raspberry Pi sensor dashboard with Flask
11 checks for this build on the board. Work from the top: power first, then each part, then the code.
0 of 11 checked
Power🔧 DC volts, 20 V rangeCheck 1 of 11
board supply pin
Plug the board into USB. Black probe on a GND pin, red probe on the 5V pin of the board.
You should see: 4.6 to 5.3 V
Readings are compared with the ranges for this build's parts. A meter on the wrong range or a loose probe gives odd numbers: check those first.
Common faults in this build
Nothing in i2cdetect: what should I check?
I2C not enabled, or SDA/SCL swapped. Check pins 3 and 5.
externally-managed-environment" error: what should I check?
Bookworm blocks system-wide pip. Use the virtual environment as shown.
Humidity missing or 0: what should I check?
Your board is a BMP280 (no humidity). Check the chip marking.