Projects / Open sump lid alarm / Fault finder

Fault finder: Open sump lid alarm

12 checks for this build on the Nano. Work from the top: power first, then each part, then the code.

0 of 12 checked
Power🔧 DC volts, 20 V rangeCheck 1 of 12

Nano supply pin

Plug the Nano into USB. Black probe on a GND pin, red probe on the 5V pin of the board.

You should see: 4.6 to 5.3 V

V

Readings are compared with the ranges for this build's parts. A meter on the wrong range or a loose probe gives odd numbers: check those first.

Common faults in this build

Siren is on all the time: what should I check?

Your relay board switches on with HIGH, so swap the HIGH and LOW in setSiren().

Siren never sounds: what should I check?

Check the siren is wired to COM and NO, and that the 12 V adapter is plugged in.

Alarm starts with the lid shut: what should I check?

The magnet is too far from the switch, so bring them within a centimetre.

Nano resets when the siren starts: what should I check?

Keep the 5 V converter wires away from the siren wires and add a 100 uF capacitor across the Nano power.

Upload fails: what should I check?

Choose the Old Bootloader option for the Nano.