Fault finder: Non-contact tank level indicator

9 checks for this build on the Nano. Work from the top: power first, then each part, then the code.

0 of 9 checked
Power🔧 DC volts, 20 V rangeCheck 1 of 9

Nano supply pin

Plug the Nano into USB. Black probe on a GND pin, red probe on the 5V pin of the board.

You should see: 4.6 to 5.3 V

V

Readings are compared with the ranges for this build's parts. A meter on the wrong range or a loose probe gives odd numbers: check those first.

Common faults in this build

Readings inverted: what should I check?

Change WET_IS_HIGH to false.

Sensor never triggers: what should I check?

The wall is too thick or has an air gap, stick it flat.

Sensors trigger together: what should I check?

They are too close, space them further apart.

LEDs blink all the time: what should I check?

Check the order of the sensors from low to high.

False wet readings: what should I check?

A wet outside wall or a metal object nearby.