Projects / Model seismograph / Fault finder

Fault finder: Model seismograph

10 checks for this build on the Nano. Work from the top: power first, then each part, then the code.

0 of 10 checked
Power🔧 DC volts, 20 V rangeCheck 1 of 10

Nano supply pin

Plug the Nano into USB. Black probe on a GND pin, red probe on the 5V pin of the board.

You should see: 4.6 to 5.3 V

V

Readings are compared with the ranges for this build's parts. A meter on the wrong range or a loose probe gives odd numbers: check those first.

Common faults in this build

Sensor not found message: what should I check?

Check SDA, SCL and power, and the module address.

Trace always full: what should I check?

Check the sensor is fixed flat and still when you start.

Trace never moves: what should I check?

Increase the multiplier 200 in the code.

Blank screen: what should I check?

Check the OLED wires and try address 0x3D.

Sensor gets warm: what should I check?

Check it is on 5V only if its module has a regulator.