Fault finder: Min-max thermometer with LCD
9 checks for this build on the Uno. Work from the top: power first, then each part, then the code.
0 of 9 checked
Power🔧 DC volts, 20 V rangeCheck 1 of 9
Uno supply pin
Plug the Uno into USB. Black probe on a GND pin, red probe on the 5V pin of the board.
You should see: 4.6 to 5.3 V
Readings are compared with the ranges for this build's parts. A meter on the wrong range or a loose probe gives odd numbers: check those first.
Common faults in this build
Shows "Probe missing" or −127: what should I check?
The 4.7 kΩ pull-up is missing, or yellow is not on D2.
LCD backlight on but no text: what should I check?
Turn the contrast trimmer on the backpack, or try address 0x3F.
Reading stuck at 85.0: what should I check?
That is the DS18B20 power-on value. Check the probe's power wires.