Projects / Pocket metronome / Fault finder

Fault finder: Pocket metronome

12 checks for this build on the Nano. Work from the top: power first, then each part, then the code.

0 of 12 checked
Power🔧 DC volts, 20 V rangeCheck 1 of 12

Nano supply pin

Plug the Nano into USB. Black probe on a GND pin, red probe on the 5V pin of the board.

You should see: 4.6 to 5.3 V

V

Readings are compared with the ranges for this build's parts. A meter on the wrong range or a loose probe gives odd numbers: check those first.

Common faults in this build

Screen blank: what should I check?

Check the I2C address 0x3C and the SDA and SCL wires.

Number goes down when turning right: what should I check?

Swap the plus and minus on the DT line in the code.

Number jumps by several: what should I check?

A bouncy encoder, add 10 nF capacitors from CLK and DT to GND.

No click: what should I check?

Check the buzzer polarity and that it is an active type.

Tempo drifts: what should I check?

Check you did not add long delay() calls to the loop.